Water quality: reading Ukraine’s monitoring map
SaveEcoBot’s water map brings together observations of surface waters in Ukraine. Read each result together with its sampling date, unit and source: a measurement describes a particular monitoring point, not every part of a river or lake.
What is monitored on the water map
Water chemistry results come from the State Agency of Water Resources of Ukraine and other sources named in the point details. Hydrological observations, including water levels and temperature, can come from the Ukrainian Hydrometeorological Center. Different sources and indicators have different observation schedules.
A laboratory sample is an observation at a particular place and time. Its publication does not mean every substance is being measured continuously. Nearby points may cover different water conditions, and a level measured relative to a gauge’s zero is different from the river’s depth.
Start with the sampling date and available history
Open a monitoring point and check the dates of the individual indicators. The latest chemistry results and the latest water level can refer to different days. An old or missing result means there is a gap in current information; it does not mean a concentration is zero or water is clean.
The compact popup shows a selection of indicators. Open the full list and available history before drawing a conclusion. Compare the same indicator at the same point, in the same unit, while considering season and water conditions. One change between two samples is not enough to establish a long-term trend.
Indicators you may find on the map
- Dissolved oxygen
- Unit or reporting basis: mg O₂/dm³
- Oxygen present in water; a low result can matter for aquatic life.
- BOD5
- Unit or reporting basis: mg O₂/dm³
- Oxygen used in a five-day biological test; different from dissolved oxygen.
- COD
- Unit or reporting basis: mg/dm³, oxygen equivalent
- Oxygen equivalent from a chemical oxidation test; check the source notation.
- Ammonium, nitrites, nitrates
- Unit or reporting basis: mg/dm³ of the reported ion
- Different nitrogen-containing ions, measured separately.
- Nitrogen forms reported as N
- Unit or reporting basis: mg N/dm³
- Concentrations expressed as nitrogen mass, not the mass of the whole ion.
- Phosphates and phosphorus forms
- Unit or reporting basis: mg/dm³; check whether reported as P
- Phosphorus-containing nutrients; the reporting basis changes the numerical value.
- pH
- Unit or reporting basis: pH units
- Acidity or alkalinity on a logarithmic scale.
- Electrical conductivity
- Unit or reporting basis: mS/m
- Response to dissolved ions and temperature, not a test for one substance.
- Mineralization; hardness
- Unit or reporting basis: mg/dm³; mg-equivalent/dm³
- Dissolved mineral content; hardness mainly reflects calcium and magnesium.
- Metals and other trace substances
- Unit or reporting basis: mg/dm³ or µg/dm³, as shown
- Check the exact substance, measured form, unit and sampling date.
Units and the substance being reported
One milligram per cubic decimetre (mg/dm³) equals one milligram per litre (mg/L). A microgram per litre (µg/L) is one thousandth of a mg/L. Always check the unit shown by the source; a similar number with a different unit may describe a very different concentration.
Nitrate concentration and nitrate nitrogen concentration are expressed on different mass bases. The same distinction matters for ammonium and ammonium nitrogen, or phosphate and phosphorus. Do not compare their numbers directly or add them together as if they were independent quantities. pH and electrical conductivity use different scales altogether.
Dissolved oxygen, BOD5 and COD
Dissolved oxygen measures oxygen present in water and available to aquatic organisms. Its level depends on temperature, mixing, biological activity and other conditions. For an indicator with a minimum criterion, a lower concentration can be the problem: higher is not always worse across all water indicators.
Biochemical oxygen demand over five days (BOD5) measures oxygen used during biological decomposition under test conditions. Chemical oxygen demand (COD) measures an oxygen equivalent in a chemical oxidation test. These describe potential oxygen consumption, not the oxygen remaining in the water. They are different tests and do not identify one specific pollutant or its source.
Ammonium, nitrites, nitrates and phosphates
Nitrogen and phosphorus are nutrients needed by aquatic life. Excess inputs can contribute to eutrophication: increased plant and algal growth, followed by decomposition that can consume oxygen. Wastewater, runoff and natural processes can all affect the measurements; a concentration alone does not establish where a substance came from.
The map can show several nitrogen and phosphorus forms separately. Read the exact indicator name, reporting basis and sampling date. Compare nutrients with oxygen, temperature and previous samples where available. Nutrient results alone cannot confirm a toxic algal bloom or determine whether water is suitable for bathing.
pH, salts, hardness and metals
pH describes acidity or alkalinity on a logarithmic scale. Conductivity reflects the water’s ability to carry an electrical current and depends on dissolved ions and temperature. Mineralization describes dissolved mineral content; hardness is mainly related to calcium and magnesium. These are related properties, not interchangeable measurements.
Chlorides, sulfates, metals and organic substances provide additional information where they have been measured. Coverage varies by indicator and point. A low salt content does not rule out metals, pesticides or microbes, and the presence of a metal does not by itself prove an industrial source: geology and the substance’s measured form also matter.
A comparison with a standard is not a water quality class
The map compares suitable results with the criterion shown for each indicator. A maximum, a minimum and an allowed range require different comparisons. The marker colour summarizes the largest applicable ratio; its surrounding ring summarizes the number of applicable exceedances. Read the current legend and the individual rows rather than judging by colour alone.
Some criteria apply to an average over a period and cannot be assessed from one sample. Reference boundaries of quality classes, including those from DSTU 4808, have a different purpose and are not treated as single-sample exceedance thresholds. An indicator without a valid comparison still contains useful measurement information.
The complete official ecological and chemical status assessment of a water body uses a defined methodology and more evidence than one chemical reading. SaveEcoBot’s marker is a way to explore observations; it is not that official classification.
What these observations can tell you
Use the map to find observations, inspect their sources and dates, and understand which indicators changed at a monitored location. When comparing points, consider their locations and whether the samples are comparable. The map alone cannot establish who caused pollution.
Surface-water monitoring is not a certificate that water is safe to drink, prepare food with or swim in. Those questions require relevant chemical and microbiological checks and current advice from the responsible authorities. Consult local official notices for restrictions and practical decisions about water use.
Sources and further reading
- State Agency of Water Resources of Ukraine: surface-water monitoring
- Ukrainian Hydrometeorological Center: daily hydrological situation
- USGS: dissolved oxygen and water
- USGS: biochemical oxygen demand
- US EPA: dissolved oxygen, BOD and COD
- USGS: nitrogen and water
- USGS: phosphorus and water
- USGS: pH and water
- EEA: nutrients in freshwater and trend methodology